Exhaust Gas Boiler Specifications(4 Section)
Design Condition:
Normal Working Pressure :7.0 bar.g
Sat. Steam Evaporation required : 4800kg/h
Sat. Steam Pressure : 7.0 bar.g
Exhaust Gas amount at 100% engine load : 52800kg/h X 4 SETS
Exhaust Gas Inlet Temperature (100% Load) : 351 C
Exhaust Gas Outlet Temperature : 281 C
Feed Water temp, : 70 C
Design Pressure :10.0 bar.g
Hydrostatic Test Pressure : 15.0 bar.g
Performance of EGB:
1. Sat. steam evaporation : 4800 kg/h @170.5 C
2. Sat. steam temperature: 170.5 C
3. Heating surface :428.0 mXm
4. Total draft loss of boiler:MAX. 100mmAq
2. Sat. steam temperature: 170.5 C
3. Heating surface :428.0 mXm
4. Total draft loss of boiler:MAX. 100mmAq
Exhaust Gas Boiler Specifications(3 Section)
Design Condition:
Normal Working Pressure:7 bar.g
Sat. Steam Evaporation required: 3600kg/h
Sat. Steam Pressure : 7.0 bar.g
Exhaust Gas amount at 100% engine load: 52800kg/h X 3 SETS
Exhaust Gas Inlet Temperature (100% Load) : 351 C
Exhaust Gas Outlet Temperature : 281 C
Feed Water temp, : 70 C
Design Pressure : 10.0 bar.g
Hydrostatic Test Pressure : 15.0 bar.g
Performance of EGB:
1. Sat. steam evaporation : 3600 kg/h @170.5 C
2. Sat. steam temperature: 170.5 C
3. Heating surface :321.0 mXm
4. Total draft loss of boiler:MAX. 100mmAq
2. Sat. steam temperature: 170.5 C
3. Heating surface :321.0 mXm
4. Total draft loss of boiler:MAX. 100mmAq
OIL FIRED BOILER SPECIFICATION
DESIGN CONDITION
1) Steam production :3,000 kg/hr
2) Working pressure : 7.0 bar.g
3) Design pressure : 10.0 bar.g
4) Feed water temperature: 70 ·C
5) Ambient temperature: 45 ·C
6) Fuel oil consumption: 282.6 kg/hr
7) . Air consumption: 5826.5 kg/hr
2) Working pressure : 7.0 bar.g
3) Design pressure : 10.0 bar.g
4) Feed water temperature: 70 ·C
5) Ambient temperature: 45 ·C
6) Fuel oil consumption: 282.6 kg/hr
7) . Air consumption: 5826.5 kg/hr
8) Fuel gas flow amount : 5950.3 kg/hr
9) Fuel gas temperature: Max. 470 ·C
10) Fuel gas draft loss: Abt. 150 mmAq
11) Fuel oil : MDO (Marin Diesel Oil)
10) Fuel gas draft loss: Abt. 150 mmAq
11) Fuel oil : MDO (Marin Diesel Oil)
PARTICULARS OF OIL FIRED BOILER
1. Safety valve setting pressure : 9.0 bar.g
2. Dimensions of overall casings :
- Outside diameter (exclude insulation) :2930 mm
- Length of boiler drum (exclude insulation) : 4411 mm
- Flue gas outlet size : 600 A
3. Volume of Auxiliary boiler :
- Water volume at normal water level : 18.62 m3
- Steam volume at normal water level : 5.3 m3
4. Weight of Auxiliary boiler
- Operating: 36 ton
2. Dimensions of overall casings :
- Outside diameter (exclude insulation) :2930 mm
- Length of boiler drum (exclude insulation) : 4411 mm
- Flue gas outlet size : 600 A
3. Volume of Auxiliary boiler :
- Water volume at normal water level : 18.62 m3
- Steam volume at normal water level : 5.3 m3
4. Weight of Auxiliary boiler
- Operating: 36 ton
- Dry (excluding of burner and fittings) : 17 ton
- Dry (including of burner and fittings): 18 ton
- Dry (including of burner and fittings): 18 ton
MATERIAL
1) Shell : S841 0
2) Tube: ST8H340
3) Chamber: SS400
4) Insulation: Mineral wool (100t)
3) Chamber: SS400
4) Insulation: Mineral wool (100t)